Instructions, safety and tips and tricks

Many home owners choose to install their own insulation. Installing insulation incorrectly can be dangerous and can reduce the effect of the insulation by up to 50%. If you choose to do it yourself, we strongly recommend that you familiarise yourself with the proper process and the relevant standards prior to commencing the installation.

In this section of our website we have collected a number of links, safety considerations and tips and tricks which have helped us over the years. By providing this information Simplee Insulation does not recommend that your install your own insulation, and we do not accept any responsibility for consequences arising from your decision to install your own insulation.

 

Call Simplee on (03) 9021 3759 for a free assessment of your insulation needs!

 

 

D.I.Y. insulation instructions

D.I.Y. insulation instructions

Do not start work until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999:1992

Step 1
Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Start from the furthest point-ensuring the top plate (top of the wall) is covered and work back towards the access hatch of the ceiling.
When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.

Step 2
The insulation may be trimmed to appropiate sizes if required.
Make sure that you leave sufficient clearances around recessed lights, extractor fans, chimney elements and piping as appropiate.
Where possible, place insulation under electrical cables and ductwork.
Use any off-cuts to fill voids.
Glue or fix insulation to the back of the access lid or hatch.

Step 3
Always make sure your insulation has a snug fit, with a uniform finished height of insulation. Check tips and tricks for good techniques in achieving this.

Step 4
Once you have completed your installation make sure you keep a copy of the product specification together with the documentation of your house.

Knauf instruction video

In this video we show you how quick, clean and easy it is to install EarthWool Insulation in the ceiling of your home.

 

Download instruction sheets

EARTHWOOL CEILING ROLL INSULATION

EARTHWOOL CEILING BATT INSULATION

Do not start work until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999-1992

Step 1
Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Work progressively around the perimeter of the building/room.
When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.

Step 2
The insulation may be trimmed to appropiate sizes if required.
When cutting to fill a void, oversize by up to 10mm to ensure a snug fit
Do not leave folds of or compress the insulation material
Fill gaps around lintels, double framing, windows and doors with off-cuts
Trim and place product around vents to allow ventilation systems to operate as intended
Shape and fit insulation behind electrical wiring and plumbing work
Use string to hold in place (if required)
Ensure batts do not protrude beyond the line of the studs.

Step 3
Always make sure your insulation has a snug fit, with a uniform finished height of insulation. Check tips and tricks for good techniques in achieving this.

Step 4
Once you have completed your installation make sure you keep a copy of the product specification with the documentation of your house.

Knauf instruction video

In this video we show you how quick, clean and easy it is to install EarthWool Insulation in the walls of your home.

 

Download instruction sheets

EARTHWOOL WALL BATT INSULATION

Do not start work until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999:1992

Step 1
Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
The insulation should always be fitted with strapping
If fitted to fold down the fold should be no more that 75mm below the bottom of the product
Start from the furthest point ensuring the bottom plate is covered and workback towards the access entrance of the underfloor
When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.

Step 2
The insulation may be trimmed to appropiate sizes if required.
Place insulation in accordance with AS3999:1992, ensuring appropiate clearances from recessed lights, plumbing, extractor fans, chimney elements and piping
Refer to relevant standard for guidance regarding placement of insulation and staping around electrical wiring.
EXTREME CAUTION REQUIRED
If insulation is covering any wires, apply the Electrical Hazard labels at that point

Step 3
Place long edge side of the insulation first neatly into the joist/underside of floor intersection
Pressure fit the body of the insulation flush up under the floor
Fold the opposite edge down so that a snug fit is achieved
Leave no gaps between the insulation and the framing and the underside of the floor
Fix strapping across the underside of the segment
Each segment should have three runs of stapping applied, one at approx. 100mm from each end and one diagonal or accross the center of the segement
Always ensure the insulation has a snug fit. Refer to the tips and tricks for techniques to reach tight spaces.

Step 4
Once you have completed your installation make sure you keep a copy of the product specification with the documentation of your house.

Knauf instruction video

In this video we show you how quick, clean and easy it is to install EarthWool Insulation in the walls of your home.

 

Download instruction sheets

EARTHWOOL UNDERFLOOR INSULATION

 

Basic principles of insulating

The following installation principles will ensure the best possible performance from insulation.

  • Avoid gaps in insulation
  • Do not compress bulk insulation
  • Eliminate thermal bridges (e.g. metal framing, steel beams)
  • Allow clearance around appliances and fittings
  • Protect insulation from contact with moisture
  • Provide a sealed air space with reflective insulation
  • Provide vapour and moisture barriers to prevent condensation

Tips to improve thermal performance

  • Fit batts snugly leaving no gaps around ducts and pipes
  • Make sure corners, junctions of wall-floor-ceiling are fully covered
  • Isolate metal framing from contact with cladding
  • Insulate window frames or install windows with thermal breaks

Insulation clearance requirements

Some appliances and fittings, such as recessed downlights and heater flues, require free space around them for the dissipation of heat, to reduce fire hazard. Insulation should not be placed against these fixtures.

  • Recessed downlights – Minimum clearance of 25mm
  • Flues and exhaust fans – Minimum clearance of 25mm
  • Electrical wiring – Keep wiring clear of insulation (check with electrician before installing insulation)

Condensation

Insulation, correctly installed, can keep the interior surface temperature of ceilings and external walls above the dewpoint, preventing condensation on these surfaces. Condensation control involves preventing moist air from coming into contact with cold surfaces below the dewpoint of the air by one or more of the following means:

  • Good ventilation of the moisture-laden air
  • Insulation to keep ceiling and wall temperatures above dewpoint
  • Heating to prevent indoor surfaces from cooling below the dewpoint

Protect insulation from contact with moisture

Masonry walls are not waterproof. In both brick veneer and double-brick wall construction a cavity between the external masonry wall and the internal lining keeps the internal lining dry. Moisture on the internal face of the external masonry wall can drain away through weepholes or evaporate into the cavity.

  • Brick veneer construction – make sure the insulation remains within the frame. Use reflective foil, galvanized wire or building paper to keep the bulk insulation in place
  • Cavity masonry walls – restrain bult insulation to maintain at least 30mm cavity
  • Existing wall cavities – use ‘cavity fill’ water-repellent loose-fill granular rockwool insulation. This material contains a water repelling agent to prevent absorption of moisture.

Sealed air space with reflective foil

  • Reflective insulation adjacent to a solid surface without an airspace, has no insulative value and acts only as a vapour barrier. To add thermal resistance, reflective insulation must face a sealed air space.
  • Maintain a sealed air space of at least 25 mm;
  • Eliminate air movement between air spaces on either side of the foil;
  • Overlap sheets by 150 mm and tape over joins; seal any gaps;
  • Use face-of-wall brick ties instead of ties which penetrate the foil;
  • Reflective surfaces should be kept clean and dust free, vertical installation is best for this.

It’s important that insulation is installed correctly to meet Australian standards. It is safer to have insulation installed by a reputable licensed installer. Installing insulation carries potential risks and may require expert knowledge and assistance. Some types of insulation require the use of specialised equipment, masks and protective clothing. Electrical and fire safety are particularly important issues.

Clearance around appliances and fittings

Some appliances and fittings, such as recessed downlights and heater flues, require free space around them for the dissipation of heat, to reduce fire hazard. Insulation should not be placed against these fixtures. Regulations and manufacturers’ recommendations should always be checked before installing insulation.

Rules of thumb – insulation clearance requirements

  • Recessed downlights – Minimum clearance of 25mm
  • Flues and exhaust fans – Minimum clearance of 25mm
  • Electrical wiring – Keep wiring clear of insulation (check by electrician before installing insulation)

Caution when using foil products

  • Keep foil products away from electrical power uitlets or lights as they can conduct electricity through the aluminium metal reflective covering.
  • Care must also be taken when installing under metal or tile roofs.

Protective clothing

  • Always wear goggles, a dust mask, gloves, long pants and a long sleeve shirt when putting in roof insulation.

 

Tips and tricks

Tip 1 – Preload the ceiling before plastering
If you are building a new home it is a good idea to get the insulation above the ceiling before the roof space is enclosed.

Tip 2 – Handy stick for tight spaces
For hard to reach areas, use a broom handle with a nail through the tip to spike the batt and position it.

Tip 3 – Extra ventilation in roofspace
You need ventilation while you work. If the roof is tiled, kick back some tiles for ventilation.

Tip 4 – Hot weather
Try to avoid installing on a hot day, but if you are start nice and early and drink plenty of water throughout the day

Tip 5 – Use a crawling board
Use plywood or a wooden plank ca.18x400x1200mm to support yourself over the ceiling rafters.

Tip 6 – D.I.Y. Non-itch insulation
Knauf Insulation EarthWool® DIY Multi-Use Roll is a new generation of softer, safer and more environmentally friendly glasswool insulation specifically designed for DIY installation. The packaging is conveniently sized to be easily transportable and its 90mm thickness enables use in walls or for top-up insulation in ceilings.

Contact us for a free assessment of your insulation needs!